Gas Logs Set Into a Fireplace We Have Looked Up First

Gas logs keep the open fireplace and use its old flue.

Book This Visit

What We Look At

A vented gas log set sends its exhaust up the same flue a wood fire used, so the flue has to be sound and the damper has to stay open. We measure the firebox, choose a set that leaves room around the logs and fit a damper clamp. Before the install we look up the flue for cracked tiles or debris. Existing sets that soot get reset to the maker's layout.

Flue looked at before install
Set chosen to fit the box
Damper held open by a clamp
Logs set to the maker's layout
Sooting sets cleaned and reset

Fitting a Gas Log Set to the Firebox and Flue

A gas log set has a burner pan, a valve, a set of molded ceramic logs and some ember material that glows on the burner. Sets come in sizes, and the right one fits the firebox with space around the logs, so the flame does not hit the back wall too hard. We measure the front width, back width, depth and height of the firebox before recommending a set. Most installs here are vented sets, which give a tall, yellow flame that looks like wood and send their exhaust up the existing flue. Vented sets need the damper held partly open at all times, so a damper clamp is fitted that stops the damper from closing all the way. That way the exhaust always has a path out. We fit the clamp on every install and show you where it is.

The flue matters as much as the logs. Gas exhaust is warm and wet, and in an old clay flue it can loosen leftover creosote from years of wood fires and wash out weak mortar joints. Before a set goes in, we sweep the flue if it has seen wood, and a Level 2 camera scan, at $375, shows whether any tiles are cracked or joints open. A flue that fails the scan should be repaired or lined before gas logs go in. The gas side is checked too: the supply line has to be sized for the burner, a shutoff valve is fitted where you can reach it, and every joint is leak-tested. What the install costs turns on the log set chosen and the gas piping it needs; that figure reaches you on paper ahead of any order.

When a Gas Log Set Soots, Smells or Will Not Light

Existing gas log sets go wrong in predictable ways. Logs get moved during cleaning and put back in the wrong order, so the flame touches them where it should not, cools, and lays soot on the logs, the firebox and sometimes the face of the fireplace. A log cracks and gets left out. Extra rocks or lava granules get piled on the burner. The pilot on a millivolt set gets dirty or the thermocouple wears, so it will not stay lit. Each has a straightforward fix: the logs reset to the maker's layout, broken pieces replaced with the right part, the burner cleaned, and the pilot assembly cleaned or its worn part changed. We photograph the layout as we leave, so anyone who moves the logs later can put them back in the right spots.

A smell that lasts more than a few minutes, or soot that comes back after the logs are set right, points higher up, to the damper or the flue. A missing damper clamp, a nest in the flue, or a cap with a clogged screen can all hold exhaust in the firebox. We check each with a light and the camera and note what we find. In Corona and nearby Riverside, Yorba Linda and Diamond Bar, many gas log sets sit in fireplaces that burned wood for decades before the switch, so a camera look at the flue is often the most useful part of the visit. Repairs are quoted in writing after we see the set and the flue. When the set is old enough that its logs and burner are no longer made, the quote shows the cost of a new set beside the cost of the repair, along with the flue findings that apply to either one.

  • Scan First
  • Seven Days
  • Paper Quotes
  • Stills in Hand
Call (951) 501-8879