Insert Liners: Sizing and Price

A fireplace insert needs a liner sized to it.

Get a Written Flue Quote

By sending, you agree Roper Chimney Pros may contact you by call, automated text or email about your request. Consent isn't required to buy. Msg & data rates may apply; reply STOP to opt out. Privacy Policy

a fire burning inside of a wood stove

An insert is two jobs: the box and the pipe above it

Most people shopping for a fireplace insert in Corona look at the front: the glass, the trim, the flame. The part that decides whether the insert works sits above it, out of sight. Exhaust from an insert travels up a liner joined at the unit collar and ending at the crown. Get that liner wrong and the nicest insert on the market will smoke, stain its glass, or vent poorly.

So when Roper Chimney Pros quotes an insert, the first visit looks up, not at the showroom brochure. The camera goes down the flue, the opening and the flue are measured, and the quote is written for the insert and the liner together.

Why the old flue cannot just carry the insert

An open masonry fireplace was built with a big flue, because an open fire moves a lot of air and smoke. An insert burns in a sealed box and sends a much smaller, cooler stream of exhaust up the chimney. Push that small stream into the big old flue and it slows down, cools, and in a wood insert leaves creosote along the way. In a gas insert, the manufacturer sets the vent size and type, and an oversized tile flue does not meet it.

The liner solves both. It matches the flue to the appliance, from the connector at the top of the insert to the cap at the top of the chimney.

What the scan and the measurements check

Before an insert is ordered, the visit records:

  • The firebox opening. Width, height and depth at front and back, so the insert fits without cutting masonry.
  • The damper area. The old damper often has to be removed or blocked open to let the liner pass.
  • The flue size and route. The camera shows whether the flue runs straight or bends at an offset, which decides rigid or flexible liner.
  • The tile condition. Cracks and open joints do not stop an insert, since the liner takes over, but they decide whether the liner needs insulation for clearance.
  • The crown and cap. A new liner gets a top plate and cap, so a cracked crown is better repaired on the same roof visit.
  • For gas, the line. Whether a gas supply already reaches the fireplace, and where.

Those measurements go into the written quote. Nothing is ordered from a guess.

The installed price, and what moves it

The installed price for a gas insert in an existing fireplace is $2,650 to $5,350. That figure covers the insert, the liner sized to it and the install. Where your job lands inside the range depends on:

  • The unit. Size, heat output, and features like a blower or a remote.
  • Liner length and type. A two story stack needs more liner than a single story; an offset flue needs flexible stainless.
  • Liner insulation. Needed where the scan shows reduced clearance around the old tile.
  • Gas supply work. A fireplace with a gas stub already in place is a simpler hookup than one that needs a new line run, which is quoted in writing.
  • Masonry prep. Some fireboxes need the damper removed or the smoke shelf trimmed so the liner can turn the corner.

If you are thinking about a new location instead, a direct-vent gas fireplace in a new location is $4,300 to $8,600, with venting through a wall or the roof and no masonry chimney involved.

Wood inserts are quoted in writing after the same scan and measurements, because the unit choices and liner requirements vary too widely for a single published range.

The quickest way to a firm number is to send the quote form with the rough width and height of the fireplace opening, the number of stories, and whether a gas line runs to the hearth. We reply with the scan booking and a written quote for the unit and liner together.

Gas or wood

In Corona and the rest of the South Coast AQMD area, Rule 445 restricts wood burning in fireplaces and stoves on certain winter days. That is one reason many owners here pick a gas insert: it can run on any day, and it ends the ash and smoke. A wood insert still makes sense for owners who want wood heat and burn on permitted days. The liner work is similar either way; the unit and fuel line are what change.

When the flue footage changes the plan

Every so often the scan shows something that changes the insert job:

  • A flue so broken that the top of the stack needs a rebuild before a liner can be anchored.
  • A crown split through, which should be fixed on the same roof trip.
  • A shared stack where a furnace flue sits beside the fireplace flue, which has to stay separate.
  • A factory-built fireplace, which takes only inserts listed for that model, if any.

The quote will say which of these applies and price the extra work in writing, line by line.

What you get at the end of the install

When the insert is in, you get photos of the liner top and cap, the connection at the insert, and a run of the unit with the glass on. The paperwork lists the unit, the liner size and length, and the work done to the flue. It is the record a future buyer's inspector will ask for.

Related reading: chimney liner cost in Corona, the fireplace inserts service page and gas fireplace repair for an insert that is already in.

Book the measuring visit

Call us with the phone button on this page and say you are pricing an insert. We book the scan and measuring visit in Corona, Riverside, Yorba Linda or Diamond Bar, and the quote covers the insert and the liner in one document.

Ready to See Inside the Flue?

Roper Chimney Pros runs camera inspections, liners, inserts and rebuilds from Corona. Call to book a scan, and the report and stills come back with a written quote for any repair.

Call (951) 501-8879